+39 081 759 32 20     info@md-tech.it

i-stream hybrid

Preloaded, microincisional, totally biocompatible

PREMIUM MATERIAL

i-stream hybrid are produced from an ultra purified monomer acrylate with 25% water content and hydrophobic coated surface completely waterproof. This combines the advantages of hydrophobic and hydrophilic IOLs:
• Hydrophobic surface that avoids the risk of PCO formation
• Elastic, soft and flexible material easy to handle
• Monomeric structure with high internal memory shape that guarantees fast recovery of geometry and IOL’s optical characteristics after implantation
• Extreme biocompatible material with high UV rays absorption
• Preloaded for easy use and safety of the surgeon

i-stream hybrid - lens

360° SQUARE EDGE E DESIGN

The key element of the success of i-stream hybrid is the edge innovative design: 360° Square Edge.
• Ensures better bonding between the capsular bag and posterior surface of the IOL strongly reducing the onset of PCO
• At the same diopter, IOL achieves less thickness of those built with standard square edge
• Facilitates the centering and the IOL’s stability in the capsular bag

MISC IOL

i-stream hybrid is injectable through less than 2mm incision. The use of such a small incision has many advantages:
• No induction of post-operative astigmatism
• Rapid closure of corneal wounds
• Reduced post-operative healing time
• Minimize the inflammatory risk
• Reduces the risk of endothelial loss
• Patient satisfaction

 

SPHERICAL ABERRATION: -0,26μm

La geometria di i-stream hybrid’s design has been made to maximize your patient’s visual performances. The IOL has biconvex optic with a precise negative spherical aberration: -0,26μm. This amount is exactly needed to compensate the positive spherical aberration of the cornea, bringing back your patient’s eye to ideal condition: the one of young and emmetropic eye.

i-strea-hybrid - corneal spherical aberration amd human lens

i-stream hybrid – Details

  • Article:: ISP60H
  • Optical Diameter:: 6 mm
  • Optical Design: Biconvex
  • Haptic Total diameter: 11 mm
  • Haptic Design: Plate Haptic piece
  • Angulation: 5°
  • Material: Acrylic hydrophilic with hydrophobic coating and UV filter
  • Front surface profile: Aspherical Edge to reduce disfotopsie
  • Rear surface: 360° Square Edge optics and loops
  • Injection: Preloaded lens with sub 2,0 mm incision size
  • Recommended A Constant: 118.2
  • Optimized A constant from: SRK / T = 118.7; SRK/2 =118.9; Holladay 1 sf=1.60;
  • Ulib database: Hoffer Q pACD=5.39; Haigis a0=1.25, a1=0.40, a2=0.10

  • Refractive index: 1,46
  • Diopter Range:  wide diopter range
  • UV Filter: White UV cutoff <10% @ 370nm Natural Yellow UV Cutoff < 2% 420 nm
  • Sterilization: Steam
i-stream hybrid